Connections
|
| HYDRAULIC CONNECTIONS |
| |
Inlet |
Hose with ID of 20 mm (¾”) |
| Outlet |
Hose with ID of 40 mm (1½”) |
| ELECTRICAL CONNECTIONS |
| |
Voltage |
12 Vdc |
24 Vdc |
230 Vac |
| Minimal wire gauge up to 5 mt (<15 feet) |
6 mm2 (9 AWG) |
4 mm2 (11 AWG) |
0,75 mm2 (18 AWG) |
| Minimal wire gauge over 5 mt (>15 feet) |
10 mm2 (7 AWG) |
6 mm2 (9 AWG) |
1 mm2 (17 AWG |
Technical specification of the main components
|
| VORTEX DISCHARGE PUMP |
| Hydraulic performances: up to 9 mt (29 feet) vertically, up to 80 mt (262 feet) horizontally |
Voltage |
12 Vdc |
24 Vdc |
230 Vac |
| Absorption |
40 A |
25 A |
3 A |
| INLET ELECTROVALVE |
| DIRECT ACTING Version (for both fresh water and sea water inlet systems) |
Voltage |
12 Vdc |
24 Vdc |
230 Vac |
| Absorption |
80 W |
80 W |
80 W |
| SERVO PILOTED Version (for fresh water inlet only) |
Voltage |
12 Vdc |
24 Vdc |
230 Vac |
| Absorption |
15 W |
15 W |
15 W |
| INDEPENDENT INLET PUMP |
| |
Voltage |
12 Vdc |
24 Vdc |
230 Vac |
| Absorption |
3,6 A |
1,8 A |
|
| CENTRALIZED INLET PUMP (not supplied) |
| Recommended specifications |
Working pressure |
Min 1 bar - Max 3 bar |